Opis
Motorni napajalniki TeSys U je prvi inteligentni motorni napajalnik, ki združuje nadzor, preklapljanje in zaščito v eni napravi. Kompakten, preprost in modularen se prilagaja vsem aplikacijam.
Besedilo je strojno prevedeno.
Varnost izdelkov (GPSR)
Proizvajalčeva koda: LUB120
EAN koda: 3389110362794
Registrirana blagovna znamka: Schneider Electric
Ime proizvajalca: Schneider Electric GmbH
Naslov proizvajalca: Gothaer Str. 29
Poštna številka proizvajalca: 40880
Kraj proizvajalca: Ratingen
Država proizvajalca: Germany
Telefon proizvajalca: +4921173743000
Elektronski kontakt proizvajalca: https://www.se.com/
Kontakt odgovorne osebe za varnost: [email protected]
Država odgovorne osebe za varnost: Nemčija
Dokumenti
Tehnični podatki 2913800 Schneider Electric LUB120 LUB120 kontrolna enota
Tehnični podatki 2913800 Schneider Electric LUB120 LUB120 kontrolna enota
Informacije 2913800 Schneider Electric LUB120 LUB120 kontrolna enota
Informacije 2913800 Schneider Electric LUB120 LUB120 kontrolna enota
Informacije 2913800 Schneider Electric LUB120 LUB120 kontrolna enota
Navodila za uporabo in varnost 2913800 Schneider Electric LUB120 LUB120 kontrolna enota
Tehnični podatki
| Vrsta izdelka |
kontrolna enota |
|---|---|
| Proizv. št. delov |
LUB120 |
| Vrsta |
LUB120 |
| Teža |
0 |
| Width |
45 |
| Height |
154 mm |
| Depth |
126 mm |
| With transformer |
FALSE |
| Rated operation power at AC-3, 400 V |
5.5 kW |
| Number of command positions |
3 |
| Number of auxiliary contacts as normally open contact |
1 |
| Number of auxiliary contacts as normally closed contact |
1 |
| Suitable for emergency stop |
FALSE |
| Rated operation current Ie |
12 A |
| Number of indicator lights |
0 |
| Supporting protocol for LON |
FALSE |
| Supporting protocol for TCP/IP |
FALSE |
| Supporting protocol for ASI |
FALSE |
| Supporting protocol for PROFIBUS |
FALSE |
| Supporting protocol for CAN |
FALSE |
| Supporting protocol for INTERBUS |
FALSE |
| Supporting protocol for Modbus |
FALSE |
| Supporting protocol for Data-Highway |
FALSE |
| Supporting protocol for DeviceNet |
FALSE |
| Supporting protocol for SUCONET |
FALSE |
| Supporting protocol for other bus systems |
FALSE |
| External reset possible |
FALSE |
| Suitable for rail mounting |
TRUE |
| Degree of protection (IP) |
IP20 |
| Supporting protocol for SERCOS |
FALSE |
| Supporting protocol for INTERBUS-Safety |
FALSE |
| With short-circuit release |
TRUE |
| With fuse |
FALSE |
| Type of electrical connection of main circuit |
Screw connection |
| Type of electrical connection for auxiliary- and control current circuit |
Screw connection |
| Supporting protocol for AS-Interface Safety at Work |
FALSE |
| Supporting protocol for DeviceNet Safety |
FALSE |
| Supporting protocol for EtherNet/IP |
FALSE |
| Supporting protocol for Foundation Fieldbus |
FALSE |
| Supporting protocol for PROFINET CBA |
FALSE |
| Supporting protocol for PROFINET IO |
FALSE |
| Supporting protocol for PROFIsafe |
FALSE |
| Supporting protocol for SafetyBUS p |
FALSE |
| Voltage type for actuating |
AC/DC |
| Type of motor starter |
Direct online starter (DOL) |
| Rated operation power at AC-3, 230 V, 3-phase |
3 kW |
| Rated power, 460 V, 60 Hz, 3-phase |
5.5 kW |
| Rated power, 575 V, 60 Hz, 3-phase |
5.5 |
| Rated operation current at AC-3, 400 V |
12 A |
| Ambient temperature, upper operating limit |
70 °C |
| Rated conditional short-circuit current, type 2, 400 V |
50000 |
| Rated conditional short-circuit current, type 2, 230 V |
50000 |
| Rated conditional short-circuit current, type 1, 480 Y/277 V |
10000 |
| Rated conditional short-circuit current, type 1, 600 Y/347 V |
4000 |
| Coordination class according to IEC 60947-4-3 |
Class 2 |
| UKCA |
da |

0 od 5